@AlborsJose Still the same technique in past 15 years. No bioglue, no felt, and hemiarch, and selective zone 1-3 arch replacement. What is the standard technique?
We also found a positive volume-outcome relationship for AAE during AVR: Hospitals performing just 12 or more during the study (avg >1 per yr) had lower mortality at 30 d, 1 yr, & 5 yrs compared to hospitals doing <1 per year #STS2026@TsuyoshiKaneko1@WashU_CT@STS_CTsurgery
@pomyers@VictorDayan1 That’s beyond me. Mean Gradient has been 5-7 mmHg when patients awake during follow up. We copied directly from echo reports. The measurements of gradient have been consistent in patients
@pomyers@VictorDayan1 We plan to continue to follow those pts for 10-20 years and see long term outcomes. Also collaborating with our echocardiographer to review the all the Echos.
@pomyers@VictorDayan1 The echo data of the TAVR group were from the same clinical lab. In the study, TAVR is smaller than the native annulus, is the limiting factor of flow. The EOA is quite consistent in TAVR group.
@pomyers@VictorDayan1 The echo data are from the clinical echo labs who are completely blinded to this retrospective study. Size 27 and 29 valves. Have diameter above 2 cm and area above 3 cm2. Area of Normal human aortic annulus is 3-5 cm2. I am not surprised.
@VictorDayan1 EOA is calculated from LVOT, with the regression of LVH, the LVOT increases about 10% in our follow up data, the EOA continued to increase. With large valves, size 29, 27, the valve is not limiting factor of flow. With small valves, the limiting factor is always the valve.
SAVR +Y-incision AAE outperforms TAVR in hemodynamics in low-intermediate risk patients with severe AS during 3 years f/u. see our paper in JTCVS ENDO, (Fig below: mean G and EOA; PPM.) https://t.co/W15ZsM7qKu
This is why Ross, upsized Bentall, Ozaki and Y-AAE work so well for valvular AS without enlarging the LVOT. The LVOT is normal in AS patients. NO need to enlarge the LVOT. subaortic web and HOCM are different diseases, can be treated with web resection and myectomy.
With complete transaction of the ascd aorta for Y-AAE, it is very easy to access the MV through the dome of LA since MV is right underneath the root. This approach can be used for concomitant MV repair, replacement or LA Maze, LAA excision.
Deep dissection is critical to achieve a competent aortic valve in David procedure. It can be challenging when the R cor sinus is ventricularized and VAJ is high. This video shows how to perform deep dissection without worry about RVOT injury for perfect David procedure.
Right Ventricular Outflow Tract Injury During Deep Dissection in Valve-Sparing Aortic Root Replacement
This excellent video from @SanjRamdeen and @BoYangMD showcases an RVOT injury and its subsequent repair during a David procedure.
🔗https://t.co/nQSfbetSgg
#RVOT#surgery
Join us at the 39th EACTS Annual Meeting! Prof. Michael Borger and Dr. @BoYangMD will unveil a new double annular enlargement technique.
View the programme: https://t.co/PIRXPXqktR