Below ground damp proofing system applied to this partially earth retaining basement in New Cross, South East London (SE14) using Wykamol Hydradry tanking slurry. As the walls were in poor condition, we applied two dubbing out coats prior to the application of the Hydradry
Deck waterproofing undertaken at Imperial College Business School, Kensington (SW7) using Newton PolyMaxx HA hand applied polyurea waterproofing membrane.
We have previously undertaken Type C waterproofing to over 20 underpavement vaults within this building.
#apgooch
This property in South East London (SE18) was suffering from widespread rising dampness and associated hygroscopic salt contamination despite the presence of a dense internal render system. We installed a chemical damp proof course and applied 3mm meshed ventilated membane.
Newton Hydrobond pre-applied Type A waterproofing membrane applied beneath the floor slab on this project in Dulwich, South London (SE21).
Stepoc blockwork will be constructed to form the basement; we will then return to Install Newton Hydrobond 2K Flex and Geotextile membrane
Type A & Type C combined waterproofing systems installed in North West London (NW11), using Delta Membranes products. This included a large rear soffit area, beneath the rear podium deck. Always a pleasure working with London Structures.
#londonstructures#deltamembranes
n Fulham again with London Structures to provide a @delta_membranes cavity drainage membrane system with Edincare ground water and foul water drainage systems. We will be back here to install the sump pumps in a few months.
#apgooch#londonstructures#basementwaterproofing
Third time lucky!
This garden house in North West London had been "waterproofed" twice before at considerable cost to the property owner. There was no ground water sump system; the previous contractor had connected the drainage into the foul sump system.
Excellent detailing around the lightwell threshold on this project in W4 using @delta_membranes products. Another basement waterproofing and foul pumping system designed and installed by AP Gooch on behalf on London Structures.
#londonstructures#apgooch
Cavity drainage membrane system installed on this basement project in W6. The basement walls were rendered to provide a flat substrate for the waterproofing and finishes. Pre-treated timber battens will be fixed into the membrane fixings to accommodate plywood and plasterboard.
When waterproofing a basement It is important to isolate internal partitions from the external walls. On this project in Kensington we have installed starter strips of wall membrane so the partition wall can be constructed, to divide this property into separate units.
2 w
As with all trades the quality of work is really shown in the details; and we are proud to be among the best in the business when it comes to basement waterproofing. This project in Highbury has been completed to our usual high standards to protect this basement.
#apgooch
Back to this project in Cockfosters to seal the service penetrations using Newton Stopaq which is installed around the penetration, then pointed in using repair mortar to retain the Stopaq which swells when by contact with water. #basementwaterproofing#newtonwaterproofing
Edincare foul water and Delta Membranes ground water pumping systems cleaned out, pumps installed, discharge pipework connected, electrical connections and alarms installed. Final commission undertaken and hand over to the client.
Damp proofing to the lower ground floor of this office in Baker Street (NW1) using Wykamol 3mm meshed membrane; taking care to prevent damage to electrical cables and detail around the recess for the new surface mounted electrical sockets.
Waterproofing to the swimming pool structure on this project in Hampstead (NW3) using Wykamol waterproofing products. Modular drainage was installed by the contractor which drains any water ingress behind the waterproofing into our sump system. #apgooch#wykamol
Precision damp proof course insertion works using a laser level on this Central London project. Approximately 250 linear metres of damp proof course insertion to carry out using Wykamol Ultracure damp proofing cream, following by the application of a cementitious tanking slurry.