If you're studying for cardiology boards or an imaging exam, the practice sets at https://t.co/EMUduPGSgM are free. You can go question by question with explanations, or sit a full exam and see where you stand.
Diastolic dysfunction: 2016 vs 2025 ASE guidelines. What really changed?
2016: e′, E/e′, LAVI, TR velocity. Frequent indeterminate results.
2025: Stepwise algorithm, more emphasis on LAP, added LA reservoir strain, pulmonary vein flow & IVRT when needed. New pathways for special populations and HFpEF.
But here’s the question: are we improving diagnostic accuracy or just reclassifying more patients?
How has this changed your daily echo reporting?
Echo boards: normal EF, and LA pressure comes down to three numbers
EF is normal, so the 2016 ASE algorithm asks three things and needs two of them positive.
Average E/e' above 14.
TR peak velocity above 2.8 m/s.
LA volume index above 34 mL/m2.
Two or three positive means elevated LA pressure. Zero or one means normal. With only one of the three measurable the study is indeterminate, and that is a real answer the exam will offer you.
When EF is reduced the entry point changes. There you start at E/A: below 0.8 with an E wave of 50 cm/s or less is grade I, above 2 is grade III, and everything in between comes back to the same three criteria.
Septal e' below 7 and lateral e' below 10 identify impaired relaxation. They establish that diastolic function is abnormal and they do not estimate filling pressure on their own.
#ASCeXAM #boardreview #highyield #diastolicfunction #CardioBoardExam
31yo woman, 3 weeks postpartum, sudden severe chest pain.
Troponin raised
ECG: T wave inversion in the anterior leads
Angiography: long smooth narrowing of the mid LAD, no atheroma elsewhere, TIMI 3 flow
What is the management?
A. Stent the lesion
B. Conservative management with medical therapy and observation
C. Urgent CABG
D. Thrombolysis
Spontaneous coronary artery dissection. The lumen is compressed by an intramural haematoma, and postpartum is one of the classic settings.
Stenting the segment often extends the dissection, because the wire and the balloon are working in a diseased wall. Most SCAD heals on its own when flow is preserved.
Intervention is held back for ongoing ischemia, haemodynamic instability or left main involvement. TIMI 3 flow with a stable pt is the conservative case.
Cardiac CT: 60 percent stenosis, FFR-CT comes back at 0.85
Anatomy and physiology disagree often. A lesion in the 50 to 70 percent range says very little on its own about whether flow is limited.
FFR-CT models the pressure drop across that lesion from the dataset u already have. No extra contrast, no adenosine. At or below 0.80 it is treated as haemodynamically significant. 0.85 sits above the cutoff, so this one gets medical therapy.
Image quality decides whether the number means anything. Motion, misregistration and heavy calcium all degrade it, and a poor dataset can still return a great looking figure.
TAVR planning CT on a severe AS pt.
Annulus area 480mm2
Left coronary height 8mm
Sinus of Valsalva diameter 27mm
Bulky calcified left cusp
Which of these is the concern?
A. The annulus is too large for any available valve
B. Risk of coronary obstruction during deployment
C. The sinus dimensions preclude a transfemoral approach
D. Nothing here is unusual
Coronary height under 10mm with a shallow sinus and a bulky cusp is the combination that pushes the native leaflet across the coronary ostium as the valve expands.
Under 12mm gets attention. Under 10mm with a sinus under 30mm is the high risk set, and it is a reason to plan leaflet modification, a snorkel stent or a surgical approach instead of proceeding as routine.
Annulus sizing is measured in systole for TAVR, which is the opposite of most echo measurements, because the annulus is largest then.
B.
Cardiology boards: two waiting periods before a primary prevention ICD
EF 35 or less, NYHA II or III, on guideline directed therapy for at least 3 months, with a reasonable expectation of surviving a year in good functional status.
Then the waits.
At least 40 days after a myocardial infarction.
At least 90 days after revascularisation.
Both exist because EF recovers in that window often enough that an early device gets implanted for a number that no longer applies. Reassess before the referral goes in.
NYHA IV is outside primary prevention territory unless CRT, transplant or an LVAD is in the plan.
#ABIM #boardreview #highyield #heartfailure #CardioBoardExam
Cardiology basics: S3 in a 24yo athlete and in a 68yo with dyspnoea
An S3 is heard in two pts: a 24yo endurance athlete and a 68yo with exertional dyspnoea and raised JVP.
What accounts for the difference in significance?
A. The sound is produced by different structures in each
B. S3 reflects rapid early diastolic filling, which is normal in a compliant young ventricle and abnormal in a stiff or volume loaded one
C. S3 in the young pt originates from the right ventricle
D. The older pt's sound is actually an S4
S3 comes from the abrupt deceleration of blood during rapid early filling. In a young compliant ventricle with high filling volume that is a normal finding.
In an older pt it signals a ventricle that cannot accommodate the volume arriving, which is why it correlates with raised filling pressures and heart failure.
S4 is the other one, late diastolic, atrial contraction into a stiff ventricle, and it is absent in atrial fibrillation because it needs organised atrial contraction.
B.
@TJHeartFellows@UpstateCardiol1@TempleCards@LUcardsfellows@BeaumontCards@waynecardio@MGHCVFellows@UCSF_CVfellows@InovaCVFellows@SIUcardsfellows
Cardiology basics: the four pressures that explain most murmurs
A valve lesion is a pressure problem, and the gradient tells u when the murmur happens.
Systolic ejection murmurs come from flow across a narrowed outflow while the ventricle is ejecting. AS and pulmonic stenosis. Crescendo decrescendo, because the gradient rises and falls with ejection.
Holosystolic murmurs come from a pressure difference that exists throughout systole. MR, TR, VSD. The ventricle is always higher than the atrium, so the sound is flat across the whole of systole.
Early diastolic murmurs come from regurgitation back into a ventricle as it relaxes. AR and pulmonic regurgitation. Decrescendo, following the falling gradient.
Mid to late diastolic murmurs come from flow across a narrowed inflow valve during filling. MS and tricuspid stenosis.
Work out which chambers are connected and when the pressure difference exists, and the timing follows without memorising a list.
Free study mode on CardioBoardExam explains each one as u go.
@TJHeartFellows@UpstateCardiol1@TempleCards@LUcardsfellows@BeaumontCards@waynecardio@MGHCVFellows@UCSF_CVfellows@InovaCVFellows@SIUcardsfellows
Cardiology basics: the a wave is gone. what does that tell u?
Jugular venous waveform on a pt with palpitations. The a wave is absent throughout.
What does this indicate?
A. Tricuspid regurgitation
B. Atrial fibrillation
C. Complete heart block
D. Constrictive pericarditis
The a wave is atrial contraction against a closed tricuspid valve. In atrial fibrillation there is no organised atrial contraction, so the wave disappears entirely.
Complete heart block gives the opposite finding, intermittent cannon a waves, when an atrium happens to contract against a shut valve.
Tricuspid regurgitation produces a large v wave. Constriction gives a prominent y descent and Kussmaul sign.
So an absent a wave is a rhythm finding before it is a structural one.
B.
#ABIM #boardreview #practicequestions #cardiacphysiology #CardioBoardExam
Cardiology basics: preload rises, afterload rises. which curve moves?
A pt is given a pure arterial vasoconstrictor. Heart rate and contractility are unchanged.
What happens to stroke volume and to the end systolic pressure volume relationship?
A. Stroke volume falls, the ESPVR line is unchanged
B. Stroke volume falls, the ESPVR line shifts down and right
C. Stroke volume rises, the ESPVR line is unchanged
D. Stroke volume is unchanged because contractility did not change
The ESPVR is a property of the muscle. Its slope is contractility, so nothing but an inotropic change moves it.
Raising afterload makes the ventricle eject against a higher pressure, so it ejects less. The end systolic point slides up the same ESPVR line, end systolic volume rises, and stroke volume falls.
D is the nasty on. Stroke volume depends on preload, afterload and contractility together, so holding one constant does not hold the output constant.
A.
#ABIM #boardreview #practicequestions #cardiacphysiology #CardioBoardExam
Echo boards: u measured LVOT diameter 2mm too small. what happens to the AVA?
You calculate aortic valve area by continuity. The LVOT diameter is measured as 1.9 cm when it truly is 2.1 cm.
What happens to the calculated valve area?
A. Underestimated by about 5%
B. Underestimated by about 18%
C. Overestimated by about 18%
D. Unchanged, the VTI ratio corrects for it
LVOT area uses the radius squared, so a diameter error gets squared before it ever reaches the valve area. 1.9 versus 2.1 is about a 10% error in diameter, which is roughly 18% once squared, and the area comes out too small.
Thats why a mildly stenotic valve gets reported as severe when the LVOT is undermeasured, and its the single largest source of error in the calculation. Measure in mid systole, inner edge to inner edge, 3 to 5 mm below the annulus.
B.
#ASCeXAM #boardreview #practicequestions #valvedisease #CardioBoardExam