Makers of the Dropometer. Peer reviewed drop shape analysis, built around a smartphone: contact angle, surface tension, surface energy. York U spinout.
Does it matter who takes the reading? In a DIY ImageJ setup, someone places the baseline and tangent by hand, so two people can read one drop differently. The Dropometer's automatic edge and baseline detection gives the same reading from the same image. Link in replies.
AATCC TM193 grades fabric by the lowest surface tension water and IPA mix it repels. Yet on one siloxane finish, water and IPA drops hold higher angles than alkanes of similar tension. Our TM193 page, reviewed by Dr Jinde Zhang of UMass Lowell, explains why. Page is on our site.
Our Murdoch case study includes an ROI calculator we label 'directional only, not a modelled return.' The real reported numbers: $7,485 delivered config vs $10,000+ ceiling, 120.67°/125.03° contact angles validated against a KRUSS DSA100E. Know which numbers are which.
To be fair: contact angle screening isn't a substitute for real bond testing, and for low-volume PP bonding an instrument like ours may not pencil out. It's built for recurring bonding failures where nobody has a fast way to check surface readiness first.
@StephanieGhso Ours: "ChatGPT recommended you." We sell a US$4,990 contact angle instrument to labs, and many new inquiries now say they found us through ChatGPT or a Google AI Overview, not a search or a rep. The AI shortlist is the new first sales call. https://t.co/Vagf2Vyyti
Fair's fair: for high-speed droplet impact/wetting dynamics, KRUSS DSA100E's camera (up to 3,450fps) beats Dropometer's 10fps, full stop. We built Dropometer for reliable field/QC measurement, not high-speed imaging. Buy the right tool. Comparison in replies.
DIY ImageJ is a good way to learn contact angle. When the number goes into a paper or a customer report, ask how the method was checked. The Dropometer's method was validated against a KRUSS DSA100E in peer review, with a published accuracy of 0.35°. Link in replies.
Dyne pens (ISO 8296) give a fast qualitative pass/fail, no record. Dropometer gives a documented contact-angle number + image, offline, in the field. In our assessment, that documentation gap is why dyne pens rank lowest in our buyer's guide.
USF Chemistry is part of a multi-institution study for the Journal of Chemical Education on contact angle instrumentation in teaching labs. It's underway, not published. We won't call it proof until it is. USF's own deployment: 33 units, 2+ years running. Case study below.
Honest take: not every shop needs a contact angle instrument. If bonding volume is low or failures are rare, occasional lab testing can beat a $4,990 purchase. The case gets strong with volume or safety-critical bonds, where 1-10-100 math kicks in.
Full disclosure: our Dropometer vs Ossila comparison is a spec-sheet read, not a lab test. We didn't run the two side by side. Read both datasheets, ask what conditions the numbers were measured under, test your own samples before you buy.
Link in replies.
ramé-hart Model 250: 6.3kg benchtop instrument built for one lab (their datasheet). Dropometer: built to travel, production floor, field, multiple sites. Same measurement, different question: where does your work actually happen?
Link in replies.