We're Future BY Energy Ltd, energy assessors for architects, developers and builders.
SAP, SBEM, Part O, energy statements, air, sound and vent tests. More than 17 years, nationwide.
Drawings to [email protected] or WhatsApp 07928 053322 📩
#SAP#PartO#BuildingRegs
SBEM calculations explained: the TER and TPER targets, design stage and as-built BRUKL, and the on-construction EPC 🏢
Full 5-minute guide:
https://t.co/03kUKZw1Rs
#SBEM#BRUKL
Energy statement for planning? Don't leave it late. Start it with the design stage SAP, keep the same numbers in both, and on London majors aim for 35% less carbon on site. 🏙️
https://t.co/1WpCOeXiZn
#EnergyStatement#LondonPlan
Sound testing in London: how many tests? 🔊
One set per 10 homes of the same construction. Flats: six tests. Attached houses: two.
https://t.co/6ECuTnOQd7 #SoundTest#PartE[email protected]
Energy grants 2026: the new Warm Homes loans, the £7,500 heat pump grant, the Local Grant, and ECO4 closing 31 December 🏡
Full 5-minute guide:
https://t.co/3zNLoduIhf
#EnergyGrants#WarmHomesPlan
TM52 overheating assessment in London: three tests, fail two and the room overheats. Part O only covers new homes, so offices, schools and mixed-use schemes need TM52 when planning or BREEAM asks. 🌡️
https://t.co/sBf37J3hox
#TM52#Overheating
SAP calculations in London and nationwide: thanks to Ziad for this Google review ⭐
From £100+VAT, 3 working days.
https://t.co/IgNoy58XdE #SAP#PartL[email protected]
Display energy certificate or EPC? 📊
An EPC rates how a building is built. A DEC rates how it's run, from 12 months of real energy use.
https://t.co/Qfoq3wrGTO #DEC#PublicSector[email protected]
SAP calculations explained: design stage, photos and air test on site, as-built BREL and EPC 🏗️
Full 5-minute guide:
https://t.co/8M7hEvqHpe
#SAPCalculations#PartL
TM44 inspection in London? Small split units still count. Add up every air con unit under your control: over 12 kW and it needs inspecting at least every 5 years. ❄️ #TM44#AirConditioning
https://t.co/BNf4QRYbLF
Condensation risk analysis: mould in the corner is often a cold junction, not the ventilation 🧱
We check the temperature factor (fRsi) against 0.75 for homes.
https://t.co/23g0q17LAH #CondensationRisk#ThermalBridging[email protected]
As-built BRUKL: what changes from design stage? 🏢
Changed the lighting, HVAC or glazing on site? It goes in the as-built model. SBEM from £400+VAT.
https://t.co/dJFxYE09hN #SBEM#BRUKL[email protected]
Commercial EPC for a shop and office building in Guildford, now lodged ✅ Shop on the basement and ground floors, offices above, air con that heats and cools. We model each space for how it's used.
https://t.co/tM1KKgyPYY
#CommercialEPC#EPC
Part O simplified method in London? Check your postcode ☀️
High risk areas also need shading on glazing from NE to NW via the south. From £150+VAT.
https://t.co/W3BLMpWwzF #PartO#Overheating[email protected]
Energy statement for planning: the energy hierarchy, the 35% London Plan target and carbon offsets explained 🏙️
Full 5-minute guide:
https://t.co/ODAuwftlwa
#EnergyStatement#LondonPlan
TM52 overheating assessment or TM59? 🌡️
Homes: TM59 and Part O. Offices, schools and shops without mechanical cooling: TM52. Mixed-use: both in one model.
https://t.co/duOB9rNUwo #TM52#TM59[email protected]
Design stage SAP calculation: don't leave it until you're on site 🏗️
Building control needs the figures no later than the day before work starts. From £100+VAT.
https://t.co/IgNoy58po6 #SAP#PartL[email protected]
Air test for new builds: what figure is in your SAP? 🌬️
Legal maximum 8 at 50 Pa, but the design SAP often assumes 3 to 5. Test before final decoration.
https://t.co/G3cujwD3CG #AirTest#PartL[email protected]
Display energy certificate explained: who needs a DEC, how long it lasts, and how to improve the rating 🏫
Full 5-minute guide:
https://t.co/lUWqEIUhnv
#DEC#PublicBuildings
Display energy certificate London: not a one-off. Over 1,000 m²? A new DEC every year, advisory report every 7. 250 to 1,000 m²: both last 10 years. 🏫
https://t.co/xU9hHLwPHV
#DEC#DisplayEnergyCertificate
Thermal bridging calculations: check the junctions before adding insulation 📐
Defaults overstate heat loss. Values for your real lintels, sills and eaves are often lower.
https://t.co/JnMc3nBusy #ThermalBridging#PSIValues[email protected]