From previous picture, flap was opened. How about flap design for placing implant and GBR on #7 and 10? making vertical releasing incision distal of canine? Or no vertical and just extending incision 2-3 teeth… https://t.co/2sl2VosLVM
Implant is moving, possible of screw loosening? X-ray showed some bone loss around implant but I’m not sure completely osseointegration was destroyed or not. But patient feel some pain... hmm, let me put mu finger on… https://t.co/Wpzt6VRwKj
Management of soft tissue is the key for implant surgery especially GBR. Previous failed site or infected site has heavy scar tissue means less vascular and too stiff tissue. These give… https://t.co/XhOVbdibWz
It was very sad news about terrorism from New Zealand. Like playing a game and killing people and broadcasting live streaming video, terrible.,,, RIP... crazy people want to show the power… https://t.co/04w9B0c0Jr
Bone ring technique from @straumann , very interesting approach for vertical and horizontal ridge augmentation with implant placement. I was lucky to be part of this surgery. Oh, I should… https://t.co/GwVIBOKnb2
Implant was removed due to platform fracture. Working more than 20 years, great job! Or too short? Some patient complained that thinking implant is working forever... Anyway, Removing this… https://t.co/cYqvzLwteW
There is the person who called master, kind of expert of the best. Did you see the movie “Jiro Dreams of Sushi”? talking about the sushi master in the Tokyo, president Obama came to his… https://t.co/nMDYZs7CtW
Tooth extraction due to Perio, how many teeth have you ever extracted so far? Sometime 10 teeth a day? Or 32 per person!? According to WHO, oral condition is getting better year by year… https://t.co/40U6xVk8rq
Zimmer implant was failed and we realized platform of this implant was damaged by X-ray, looks fractured but even G5? Anyway, after removal of implant, I thought implant material is G5 and… https://t.co/8AjtG7HK5L
Somehow we called this as smoky bone because how this bone looks in the CBCT, like paper thin. Hmm, take it out and place implant deeper or keep this smoky bone and do staged GBR then… https://t.co/tGqP7AMxfZ
So I couldn't post pictures Instagram somehow, anyway this patient thought toothbrush is for the teeth, not for the implant. Because there is no implantbrush, ,, hmm, interesting patient,… https://t.co/pXaZZhVY4j
Straumann PURE Ceramic Implant, looks beautiful! I never place this implant yet, BLX either... I can't wait to place these implants! Hmm, US is always behind of new stuff... I envy you… https://t.co/LtEH9RAgGR
Missing teeth #8 and 9, kind of difficult case to achieve aesthetic results especially palilla between #8 and 9. Place implant on #8 and cantilever restoration can be achieved acceptable… https://t.co/mBNLbSjBxN
I’m usually happy person and easy going guy. But sometime I get upset especially problem with my computer and data, someone is trying to hack my computer? Hmm, annoying... and this… https://t.co/b810Yy8up0
Sorry for last post, this failed implant is AB implant according to my good friend, not MIS one. Sorry MIS~~~! 😢😢😢Couldn’t recognized it. But any implant can be failed with this treatment.… https://t.co/CVGK5yNeou
3D printed model from CBCT and patients actual denture. Now we can see relation ship between bone and restoration. This case, easy to place implant however question is placing one implant… https://t.co/j1aqfnv8zL
Removing Ti-mesh is a little bit tough procedure especially partial exposure case, and loosening a lot of soft tissue and making scar tissue. However case of no exposure of Ti-mesh, easy… https://t.co/VCgODPQQ71
MIS implants were failed. Were placed outside of US however there are bone loss around implant. So these are two implant, one is short and the other is longer one. Which one implant got… https://t.co/T3JsAf1TMP
During antrostomy, you can use high speed bur or piezo, I like high speed because much faster and now we can start to see schneiderian membrane. Thicker membrane may be good for elevation… https://t.co/rGeRgjSf3q
After removal of Ti-mesh, very thin tissue layer was observed, like 0.7mm? Similar as using d-PTFR membrane, because of texture and roughness of the membrane, and always thin connective… https://t.co/LVXyi6c8yq