@November_Born94@GabbbarSingh ACH comes from CADR and room size. A CADR of about 250 m³/h gives roughly 5 ACH in a 150–180 sq ft bedroom. Then circulation decides whether that clean air actually reaches every corner. That’s why Airzone moves air across the whole room, not just around itself
@smlamit@GabbbarSingh Do look for an ACH (Air Changes per Hour) means how many times an air purifier completely filters the total volume of air in a room within one hour. An 5 ACH rating means the purifier cycles and cleans all the air in your room every 12 minutes (5 times an hour).
@smlamit@GabbbarSingh That’s CADR and circulation. A denser filter in a corner unit can still leave the far side of the room dirty. Airzone moves air across the whole room. Easy test: put an AQI sensor in the farthest corner, run any purifier for 30 mins, and see what the number says.
@smlamit@GabbbarSingh Filter grade measures how much one pass of air through the filter captures. Room air quality depends on something else: how many times the room’s air actually passes through the filter.
@hoIdmecIoser_@GabbbarSingh Hi - good catch! updated product page on the way.
btw its 1.5-2 years with typical use, and the app will remind you when to swap it.
A VC friend of mine suggested to try the Karban Air purifier. Indian patented tech, by Purdue-IIT aerospace engineer.
Unique design. Hang from the ceiling or floor, for air purification, a bladeless fan and light. Great combo. 👍 @karbantech
@aditya8993@kushalbhagia We'd love to see your CFD inputs: room height, how our outlet and filtered stream were modelled, the pollutant source, and why floor mode when Airzone is designed for the ceiling.
Better still, let's measure: Pure Plus against your unit, side by side, with PM2.5 monitors :)
@aditya8993@kushalbhagia Even so, look at the worst spots. Airzone's dirtiest zone at seated height is within ~10% of the room average (87 vs 80). The other unit's is 3–6× its average (142 and 226 vs ~40). That's our built-in circulation at work: no dead zones.
@aditya8993@kushalbhagia Lab CADR tests even use a separate fan inside the test chamber to mix the air. Airzone has it built in. So the 3,900 doesn't weaken the 250. It's what gets that clean air circulated in the entire room so it reaches you.
@aditya8993@kushalbhagia No purifier cleans a room in one pass. Air keeps cycling, and in a typical 12×12 ft bedroom 250 CMH means the room's air goes through the filter about 6 times an hour. The air that skips the filter on one pass gets cleaned on a later one.