@NephroP @NephroGuy Do you have color+continuous doppler of the tricuspid valve (from that plax inflow)? Any concern of leaflet impingement due to lead? I'm assuming severe TR based on the hepatic vein systolic flow reversal which could be load-dependent from the LV but also wondering about the lead
@MedEdPGH@PittIMChiefs@PittGIMStrong Meds, specifically recent steroid use? Absence of eos is weird. Otherwise weight changes?Exam including skin changes. Macrocytosis and anemia/tcp could also be consistent with MDS.