@SebAaltonen I'm curious if you have a need/plan to implement more granular synchronization. Split barriers exist in both APIs (though they have different semantics) and even those are more constrained that the original nogfx post.
@SebAaltonen OMMs have a few problems though. Cannot use HW texture filtering and stretched (ie far from equilateral) triangles will have stretched "texels". And while filtering over UV seams is painful, filtering over different OMM'd triangles is worse. Requires fetching connectivity data.
@SebAaltonen How would HZB work here? Dreams splatter targeted 1 point per pixel density, but still had holes, which would grow larger in higher mips of the HZB.
@NOTimothyLottes@boberfly@RightTechGadfly For general lighting as opposed to an x-ray, holes in the probes become a problem. There is no guarantee that samples that should be occluded are actually blocked from showing up in the probe unless you scatter super densely, which seems expensive with so many probes.