I have this for tomorrow. My plan. DHS the neck and plate the femur shaft.
Alternative is to retrograde the shaft and pin the head.
Who had a better plan?
@Robert_Demsky@OGdukeneurosurg@Davembmd No longer adviced to use one implant for ipsilateral nof and shaft fractures. High rate of displacement and non union if you do.