All my data is available at this Google Drive link. I know I have been getting a quite a few messages looking for it. It includes master data set, FAQ, Kid's mask recommendation and mask images
https://t.co/q1H6P2AEhk
@JonathanCrock@ukhadds It derives from workplace protection studies, where they measured respirator fit and then measured actual exposure when wearing a respirator. They determined roughly that if you had a Fit Factor of 100, you had a 95% probability of having a >10x reduction in exposure (APF 10)
[1/2]Reusable mask test done. Note filtration data is my test aerosol, my face. Data also are all using the Fix The Mask to avoid issues with face seal variation between tests. My pressure drop measurement is not great so take that with a grain of salt(±0.05 typ).
@sharidelic You can reuse N95's, if AQI in your area is good(low) then fit will be the first issue. If exposed to dense wildfire smoke I would not use them for more than a day. P100 just use until it's hard to breathe in.
Good to hear our Covid Defense Kits for people w/cancer I sent out pre-hurricane are arriving safely.
Sent out another batch today. The Kit includes a booklet, masks, air purifiers, & tests. I think people are also just happy to be treated with dignity in difficult times.
@sri_srikrishna@ukhadds@CliveBeggs I think the disconnect is that we care about the dose of virus received, so while some fraction of 0.65um particles have viable virus, they have 1/1000th amount of a 7um particle(assuming the same concentration).
Its all about computing the inhaled dose.
@AB85025310@ukhadds It depends on how the scores were collected. If done using N99/N100/FFP3 mode(no classifier) then it's hard to say which one is better in context to COVID but all would be good in my book. If using N95 mode(w/classifier) then higher score is "best", but all are good in my book
@Prusa3D you should check out what we managed to do with the latest XL 5-head printer. Co-molded silicone with water solvable BVOH molds allowed us to make some cool and intricate parts. The full stack including hardware is open-source too!
#OpenSourceHardware#3Dprinting
Cool to see the OpenRespirator, and D2S tech we have been developing, get a some traction in the maker space. Thanks @hackaday for the write-up!
https://t.co/FiGkcqnpyC
@amandalhu@ErinSandersNP@JimRosenthal4@linseymarr Device is still working and depending on the design it will vary how much you see, but causes no harm and doesn't mean its not filtering. The entrainment issue is why personal airflow designs are very hard to make work for this same reason.
@amandalhu@ErinSandersNP@JimRosenthal4@linseymarr I can't see the original tweet, but I assume its about dust on the fan blades downstream of the HEPA filter. This is super common and caused by entrainment of ambient air that gets pulled in near the fan blades. Same reason shroads on CR Boxes add more flow, stops this effect
@OpenAeros needs some help! If you have any connections with anyone familiar with IEC 61010 and CE compliance we would love to chat. We get the basics, but want some help navigating the labs & companies. Basically just need the inside scoop since this our first time.
@piera_systems I haven't measured the rooms, but per HVAC design its about 3 ACH, so this gets us closer. Note that ASHRAE 241 is per person based, so we don't care too much about eACH.
What does an extra ~2-2.5 eACH cost for a classroom? This year it was $30 for air filters and $3 in⚡️, for a whopping $1.43 per kid per year!!! Took 7 hours to do 23 rooms. This ain't rocket science.
Not a paid endorsement, no connection to brand but 0/23 failures in 3 years🤷♀️
[1/5]Summary from my lab testing. Note flowrate is a rough estimate since my bathroom..er..lab is not uniform in shape so gave my best guess of volume, seems close.
@DavidLKeating Agree that there are probably better options now. These were originally purchased in 2021. They are Intertek listed(requirement for the school), and at speed 3 put out about 230 CFM
https://t.co/ljzNgr2QRM
https://t.co/CTa4j63JOM
[1/5]Summary from my lab testing. Note flowrate is a rough estimate since my bathroom..er..lab is not uniform in shape so gave my best guess of volume, seems close.
@mnstatefair I hope this is something you can address with your security teams. COVID cases are sky high here in MN right now, and people should be able to take precautions to protect themselves and not be harassed.
Your FAQ clearly says its okay.
https://t.co/DLS3IAvIA1
@taniataylorpowe There are trade-offs with FarUVC, and school adoption to comply with various safety regulations is not trivial. This comes from a person who founded a Far UV nonprofit --->https://t.co/r1x9rHngww